DIN Rail Thermocouple Clamp Screw Type Terminal Blocks

Type:
High-current terminal block
Nominal Voltage:
1000 V
Nominal Current:
309 A
Number Of Connections:
2
Connection Method:
Screw connection
Rated Cross Section:
150 mm²
Cross Section:
35 mm² - 150 mm²
Color:
gray

 

Temperature instrumentation requires microvolt precision without signal drift. Standard connection points introduce parasitic thermoelectric voltages when dissimilar metals encounter ambient temperature variations. Screw Type Terminal Blocks engineered specifically for thermocouple circuits maintain signal integrity across harsh processing plants. Integrating an industrial din rail screw terminal block eliminates loose leads while standardizing cabinet layouts on standard 35mm rails.

Technical Strengths in Industrial Control

Signal errors often stem from mechanical fatigue and thermal expansion. Utilizing a proper thermocouple screw terminal ensures continuous conductor pressure under constant thermal cycling.

Mechanical Stability and Housing Reliability

Industrial control cabinets benefit from high-retention wiring designs:

  1. Anti-Vibration Wire Retention: The screw clamp terminal mechanism prevents conductor loosening arising from plant vibrations.

  2. High-Grade Housing: Flame-retardant PA66 insulation provides high dielectric strength and heat deflection.

  3. Low Contact Resistance: Matched alloy conductors minimize thermoelectric EMF distortion at each junction.

Selecting a certified clamp terminal block keeps low-voltage sensor loops shielded against mechanical disruption.

Technical Specifications

Standardized clamp type terminal blocks conform to industrial mounting requirements:

Specification Standard Rating
Mounting Profile 35mm Top-Hat Rail (EN 60715)
Rated Insulation Voltage 600V (Pollution Degree 3)
Tightening Torque 0.5 - 0.8 Nm
Housing Material Polyamide 66, UL 94 V-0
Operating Temperature -40°C to +105°C
Wire Cross-Section 0.2 - 4.0 mm²

Cabinet Assembly Guidelines

For streamlined cabinet deployment, follow these installation practices:

  • Strip sensor leads to the recommended 9mm gauge without nicking conductors.

  • Apply calibrated torque to secure low-impedance joints without over-compressing fine wire strands.

  • Place matching thermocouple pairs adjacent to cold-junction compensation sensors for optimal baseline accuracy.

Deploy these industrial solutions to secure stable plant instrumentation and prevent costly production downtime. Request factory quotes and technical catalogs today for immediate project integration.


Model Function Wire IEC cross-section Wire UL Thickness
JHD5-150 DIN Rail Thermocouple Clamp Screw Type Terminal Blocks 150 mm²
120 mm²
150 mm²
000 AWG
000 AWG
000 AWG
31 mm
Maximum current Number of packages Thickness/Height(DIN Rail Thermocouple Clamp Screw Type Terminal Blocks)/Width mm Rated voltage/rated current/rated cross-sectior
309 A 4 31/118.5/100 1000/309 A/150 mm²

Specfication: 

Marking tags ZB10
Screw/Tightening torque(Nm) M10/4.0
Material PA
Flame retardant rating UL-94 V0
Dimensions DIN Rail Thermocouple Clamp Screw Type Terminal Blocks

With universal mounting feet for standard top-hat(Ω profile) and G-profile DIN rail mounting.

Contact Us

Leave us a message to get a quote

Request a Quote or Technical Support

Leverage our 20+ years of manufacturing experience and joint R&D capabilities. Let us provide you with reliable, high-performance electrical solutions tailored to your project needs.

This site uses cookies

We use cookies to collect information about how you use this site. We use this information to make the website work as well as possible and improve our services.more details

WhatsApp us