Fuse Terminal Block Holder Electrical Circuit Protection
- Type:
- Fuse modular terminal block
- Fuse Type:
- Glass / ceramics / ...G / 5 x 20
- Nominal Voltage:
- 500 V
- Nominal Current:
- 6.3 A
- Number Of Connections:
- 1
- Connection Method:
- Push-in connection
- Rated Cross Section:
- 4 mm²
- Mounting type:
- DIN Rail (EN 60715)
- Compatible Rail:
- NS 35/7,5, NS 35/15
- Cross Section:
- 0.2 mm²- 6 mm²
- Color:
- black
Industrial control cabinets require reliable overcurrent isolation to prevent severe equipment damage. Incorporating reliable Fuse Terminal Blocks ensures compact wiring and rapid fault disconnection across standard DIN rail assemblies.
Circuit Protection Benefits in Industrial Cabinets
Overcurrent surges disrupt factory automation and ruin PLC modules. Installing a modular terminal block fuse holder isolates faulty branches without shutting down entire control lines.
-
Fault Isolation: Instantly decouples overloaded lines to protect downstream automation.
-
Maintenance Speed: Built-in LED indication reveals blown links without multimeter probing.
-
Space Efficiency: Slim profiles minimize cabinet footprint compared to bulky disconnectors.
JHD1-4RD Modular Specifications
Hangda designed the JHD1-4RD series to deliver robust conductivity and vibration resistance. Each fuse block terminal integrates durable PA66 housing alongside screw-clamp terminals that secure solid or stranded conductors tightly.
| Parameter | Value |
|---|---|
| Model | JHD1-4RD |
| Rated Voltage | 500V |
| Rated Current | 6.3A |
| Wire Range | 0.2 - 4 mm² |
| Housing Material | Polyamide (PA66) |
| Mounting Type | DIN Rail (TS35) |
Installation and Safe Maintenance Protocols
Routine inspections verify system reliability across control enclosures. Proper servicing of each fuse terminal requires following standardized electrical safety steps:
-
De-energize cabinet power before pulling the hinged disconnect lever.
-
Replace standard 5x20mm glass cartridges with correctly rated ampacity units.
-
Torque terminal screws to manufacturer tolerances to prevent thermal hotspots.
Optimizing Panel Uptime with Certified Solutions
Selecting compliant fuse terminal blocks prevents unexpected manufacturing downtime while ensuring international safety compliance. Hangda provides certified modular solutions designed for demanding automation environments.
| Overall Dimensions | ||||
| Width / Thickness / Height (mm) | 59/6.2/63.5 | |||
| Stripping Length | 13 | |||
| Technical Parameters | ||||
| Voltage (V) | 500 | |||
| Electric current (A) | 6.3 | |||
| Section (mm²) | 4 | |||
| Crimping Range | ||||
| Rigid Wire (mm²) | 0.2-6 | |||
| Flexible Wire (mm²) | 0.2-4 | |||
| Fusible Core | R054 Ф 5*20 | |||
| Install the Track | ||||
| Can be mounted on |
![]() |
TH35-7.5 | ||
| TH35-15 | ||||
| Partition | ||||
| Used for terminating terminal blocks to achieve electrical isolation. | ![]() |
4RDG | ||
| Test Attachment | ||||
| Test Plug: Used in conjunction with the corresponding component for circuit testing. | PS-2 | |||
| Quick-Connect Coupler | ||||
| It can be inserted directly into the center of the terminal to establish a connection between terminals. | ![]() |
2 Bit | FBS 2-6 | |
| 3 Bit | FBS 3-6 | |||
| 4 Bit | FBS 4-6 | |||
| 5 Bit | FBS 5-6 | |||
| 10 Bit | FBS 10-6 | |||
| 20 Bit | ||||
| 30 Bit | ||||
| Marker Strip | ||||
| The marking strips feature standard horizontal and vertical numbering from 1 to 600; alternatively, numbering can be applied based on technical specifications provided by the customer. | blank | middle | ZB 6 (blank) | |
| Horizontal Typing | ZB 6 (horizontal) | |||
| Vertical Typing | ZB 6 (vertical) | |||
![]() |
Both sides | BFM 6 (blank) | ||
| BFM 6 (horizontal) | ||||
| BFM 6 (vertical) | ||||
| Marking Bracket | ||||
| For detailed instructions on usage, please refer to the attached section. | ![]() |
|||
| End | ||||
| Tubular Pre-insulated Terminal | ![]() |
E4010 | ||
| Tubular Non-Insulated Terminal | ||||