Push-In Type Terminal Blocks Push Fit DIN Rail Solutions
- Type:
- Fuse modular terminal block
- Fuse Type:
- Glass / ceramics / ...G / 5 x 20
- Nominal Voltage:
- 500 V
- Nominal Current:
- 6.3 A
- Number Of Connections:
- 1
- Connection Method:
- Push-in connection
- Rated Cross Section:
- 4 mm²
- Mounting type:
- DIN Rail (EN 60715)
- Compatible Rail:
- NS 35/7,5, NS 35/15
- Cross Section:
- 0.2 mm²- 6 mm²
- Color:
- black
Loose screws, prolonged wiring hours, and cabinet space constraints cost manufacturing facilities thousands each production cycle. Direct leg-spring clamping solves these field challenges instantly. When using a push in type terminal block, wire prep drops to seconds: strip, insert, done.
Operational Advantages Inside Compact Enclosures
Rapid Wire Retention Without Retorquing
Solid conductors or ferruled leads slide directly into the stainless-steel clamping cage. Vibration testing proves that a push fit terminal block eliminates regular maintenance rounds, preventing thermal drift from loose connections.
Integrated Fuse and Indicator Protection
Blown fuses halt automated lines. Utilizing an integrated push in terminal block with a hinged fuse carrier allows immediate fault identification. Integrated status LEDs pinpoint blown links without multimeter probing across every terminal strip.
Technical Specifications
| Parameter | Rating / Specification | Reference |
|---|---|---|
| Rated Operating Voltage | 500 V / 800 V | IEC 60947-7-1 |
| Wire Range | 0.2 mm² – 4.0 mm² | DIN EN 60228 |
| Strip Dimension | 10 mm – 12 mm | Manufacturer Standard |
| Rail Compatibility | TS 35/7.5 & TS 35/15 | IEC 60715 |
| Housing Material | Polyamide PA66 | UL 94 V-0 |
Field Assembly Workflow
Switchboard builders transitioning to push fit din rail terminals achieve clean panel layouts via a four-step sequence:
-
Mount modular blocks directly onto standard TS 35 rail profiles.
-
Strip conductors to the marked gauge length.
-
Push leads firmly into the spring cage until seated.
-
Insert test plugs into upper test slots to verify circuit continuity.
Project Sourcing and Design Support
Evaluating new bill-of-materials components requires physical validation. For modular electrical panels seeking higher packing density, push in type terminal blocks provide certified vibration resistance and repeatable contact pressure.
-
CAD and STEP models ready for panel layout software
-
Free evaluation samples dispatched within 24 hours
-
Direct quotes tailored to cabinet volume requirements
| Overall Dimensions | ||||
| Width / Thickness / Height (mm) | 59/6.2/63.5 | |||
| Stripping Length | 13 | |||
| Technical Parameters | ||||
| Voltage (V) | 500 | |||
| Electric current (A) | 6.3 | |||
| Section (mm²) | 4 | |||
| Crimping Range | ||||
| Rigid Wire (mm²) | 0.2-6 | |||
| Flexible Wire (mm²) | 0.2-4 | |||
| Fusible Core | R054 Ф 5*20 | |||
| Install the Track | ||||
| Can be mounted on |
![]() |
TH35-7.5 | ||
| TH35-15 | ||||
| Partition | ||||
| Used for terminating terminal blocks to achieve electrical isolation. | ![]() |
4RDG | ||
| Test Attachment | ||||
| Test Plug: Used in conjunction with the corresponding component for circuit testing. | PS-2 | |||
| Quick-Connect Coupler | ||||
| It can be inserted directly into the center of the terminal to establish a connection between terminals. | ![]() |
2 Bit | FBS 2-6 | |
| 3 Bit | FBS 3-6 | |||
| 4 Bit | FBS 4-6 | |||
| 5 Bit | FBS 5-6 | |||
| 10 Bit | FBS 10-6 | |||
| 20 Bit | ||||
| 30 Bit | ||||
| Marker Strip | ||||
| The marking strips feature standard horizontal and vertical numbering from 1 to 600; alternatively, numbering can be applied based on technical specifications provided by the customer. | blank | middle | ZB 6 (blank) | |
| Horizontal Typing | ZB 6 (horizontal) | |||
| Vertical Typing | ZB 6 (vertical) | |||
![]() |
Both sides | BFM 6 (blank) | ||
| BFM 6 (horizontal) | ||||
| BFM 6 (vertical) | ||||
| Marking Bracket | ||||
| For detailed instructions on usage, please refer to the attached section. | ![]() |
|||
| End | ||||
| Tubular Pre-insulated Terminal | ![]() |
E4010 | ||
| Tubular Non-Insulated Terminal | ||||